Cooper Security 9751 Manuel d'installation Page 94

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 148
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 93
4. Programming
Page 86 496964
73: Level/Partition C Alarm Response
This Command sets the Alarm Response for Level or Partition C.
In a single system, the options are:
Option
0 Keypad sounders only.
1 Internal sounders and keypad sounders.
2 Local alarm (internal and external sounder only).
3 Full alarm (communication and internal/external sounders).
In a partitioned system, the options are:
Option
0 Keypad sounders only.
1 Local alarm (internal and external sounder only).
2 Full alarm (communication and internal/external sounders).
74: Level C Entry Time
This Command has been replaced by Command 203.
75: Level/Partition C Exit Time
This Command sets the Exit Time for Level or Partition C.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Vue de la page 93
1 2 ... 89 90 91 92 93 94 95 96 97 98 99 ... 147 148

Commentaires sur ces manuels

Pas de commentaire