4. Programming
40 496792
To change: Key-in: Notes Default
Test Internal Sounder 94 Internal sounders operate, press or to
end test.
Test Keypad Sounder 95 Keypad sounders operate, press or to
end test.
Engineer Walk Test* 97 Zn indication and chime operate when
* See “5. Testing”
cct open
(Clear) End walk test
Load Defaults 98 1 Load defaults
Leave Programming 99
Communications Programming
Call Mode 101 0 Disabled Y
1 Single
2 Alternate
3 Dual
Reporting Type 103 0 Fast format Y
1 Contact ID
2 SIA I
3 SIA II
4 SIA 3
5 Extended SIA 3
Static Test Call 105 A (or B) nn
00 Static off Y
nn is the time in hours A nn Static call at nn hours, 01 to 24 max.
nn is the day of the month B nn Static on day nn, 01 to 24 max.
Line Fail Response 106 0 Disabled
1 Audible Y
2 Silent
Dynamic Testing 108 0 Dynamic off Y
1 Dynamic on
Three Way Calling (UK) 109 0 Three way off Y
1 Three way on
Download Mode 110 n
Where n is one of: 0 Local PC (9752 only)
1 Remote PC Y
Rings To Answer 112 0 3 rings
Downloading option 1 5 rings Y
2 7 rings
3 10 rings
4 15 rings
5 255 rings