i-on40
Page 6
Connecting Keypads to End Station
Cable Type
In general, the control unit requires
standard 7/0.2 un-screened four core alarm
cable for wiring to keypads.
For maximum performance in harsh
environments use twisted pair cable with a
characteristic impedance of 100-120ohms
eg: CAT5 or cable designed for RS485.
Use one pair for data bus A & B. Use the
other pair for 12V & 0V.
Screened cable may prove necessary if the
installation site has equipment that
produces high levels of R.F. (Radio
Frequencies), for example welding
equipment. If screened cable is required,
you should keep to the following guidelines:
1. Avoid earth loops by connecting the
screen on the cable to mains earth at
the end station but not at the keypad.
2. The continuity of the cable screen is
most important and screens MUST be
continuous along the full length of the
cable.
3. If the cable enters any metal enclosure,
ensure the screen is isolated from the
case.
Cable Segregation
Segregate the keypad cabling from any
other wiring, such as mains supply cables,
telephone cables, computer network cables
and R.F. cables. Use cable ties to keep
cables separated.
Keep the keypad cable clear of cables
supplying sounders or extension
loudspeakers.
Cable Configuration and Length
You can connect up to four wired keypads
to the end station. You may connect the
keypads either in daisy chain (serially), or
in star (parallel) configuration at the end
station connector.
250m
terminate
terminate
Star Daisy Chain
100m
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
Figure 11 Keypad Wiring Configurations
For star configurations the cable length
from control unit to the most distant
keypad should not exceed 100m. For a
daisy chain configuration the total cable
length should not exceed 1,000m,
Connection
Figure 12 shows the wiring connections at
the keypad and control unit.
ET B A 12V 0V
Figure 12 Keypad Connection
Temination
The i-on40 data bus uses the RS485
interface. Because of this the ends of the
line in some configurations may be
terminated to improve performance in
electrically noisy environments or where
there are long cable runs. Both control
panel and keypads have a termination link
on their PCBs (see 10 in Fig 3 for the
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 27 28

Commentaires sur ces manuels

Pas de commentaire