Omit Zones
You may wish to prevent a zone causing an alarm. For
example, if you have a fire door that is normally closed
and protected by a detector you may wish to leave it
open for fresh air or to move goods in and out. To do this
the control unit allows you to "Omit" a zone.
The control unit allows you to omit a zone for one
setting/unsetting cycle. You will have to omit the zone
again for the next setting/unsetting cycle.
1. Enter the User Menu and select Omit Zones.
The display shows the first of a list of zones.
2. Press u or n to highlight the zone you wish to
omit.
3. Press CHANGE to mark the zone for omission.
The character at the end of the line changes to an
"O" to show that the zone will be omitted.
If you change your mind then press CHANGE until
the end of the line shows an "I".
4. Repeat steps 2 and 3 for any other zone you wish
to omit (or include).
5. Press DONE to store the changes you have made.