: Setting Up Shunt Groups
Shunt groups provide a simple way to
isolate zones until further notice. Each shunt
group can contain up to eight zones, and
each group can be allocated to a "Shunt"
user code. When the code is first entered,
the zones are isolated. When the code is
entered again, they are reinstated.
Although 24-hour zones are most
commonly isolated, any zone can be
assigned to a shunt group.
Z
Any zone selected must have the
Shuntable attribute set in Engineer
option 1-1.
Z
Entering a shunt code to reinstate zones
may start the exit timer, depending on
whether Unshunt, No Exit or Unshunt &
Exit is selected (Engineer option 1-9-1).
User 2 Menu 3
Edit Shunts
1. Press
[
to select this option.
Edit Shunt Grps
Group 01
2. Select the shunt group by using
|
or
¬
,
or by entering the group number (01 to
10), then press [.
Group 01 Zone >1
Zone ----
3. The first zone assigned to the group is
displayed. This is indicated by ">1" in
the top-right corner. The bottom line
indicates the zone number, or "----" if a
zone number has not yet been
specified. (See page 49 for details of
zone numbering.)