Programming - Programming Commands 9651
Page 62 11772232
Option
00 Not Used 19 Smoke Detector
01 Fire 20 Not used
02 PA 21 Battery Fault
03 Burglar 22 System Alarm
04 Open/Close 27 Not used
05 Alarm Abort 28 Not used
06 Technical Alarm 29 Not used
07 Not used 30 Pulse Set OP 1
08 RF Low Battery 31 Pulse Set OP 2
09 Supervision Loss 32 Pulse Set OP 3
10 RF Jamming 33 Pulse Set OP 4
11 AC Fail 34 Pulse Unset OP 1
12 Tamper Alarm (day tamper) 35 Pulse Unset OP 2
13 Open 36 Pulse Unset OP 3
14 Close 37 Pulse Unset OP 4
15 Zone Omitted 38 Set Fail
16 Medical Assistance 39 General Fault (Note 2)
17 Key Box 40 All Fault (Note 3)
18 Anti-Mask 41 Duress
Notes:
1. General Fault is active for all faults except AC Fail, Anti-Mask, Battery
Fault, Line Fault, Zone AC Fail, Zone Battery Fault and Zone Low
Battery.
2. All Fault is active for all faults (including AC Fail, Anti-Mask, Aux DC,
Battery Load Test Fail, Battery Missing, Comms Fail, Keypad Ident Fail,
Line Fail, Low Battery, Plugby Fail, uCom Fail, Zone AC Fail, Zone
Battery Fault, Zone Fault, Zone Low Battery and Zone Pwr O/P).
3. The control unit delays reporting/logging either mains loss, or exiting
engineering with mains loss, by 15-18 min (chosen at random). If you
select a Scandinavian default in Command 0, the control unit waits at
least 60 minutes before reporting.
4. The plug-by outputs can be tested using Command 92 (page 71).