9651 1. Introduction
11772232 Page 5
User Control
The control unit provides 50 independent User access codes and a separate
Duress Code. Users can change these codes at any time but cannot use
them to program the system. During installation, the Installer can select
whether access codes use four or six digits.
Users can set only one level at a time. Level A sets the whole system. Levels
B, C and D set parts of the system. The Installer allocates zones to levels, but
all keypads operate the entire system. There is only one sounder output for
the whole system, and you can use a loud-speaker for setting tones and local
alarms. All users belong to the whole system.