2. Programming Commands
Page 34 497096, issue 3
75: Level/Partition C Exit Time
This command sets the Exit Time for Level or Partition C.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
76: Level/Partition D Exit Mode
This command sets the Exit Mode for Level or Partition D. The keypads give a
double "beep" confirmation tone at the end of all setting modes, including
Silent Set. The default is option 0, Timed.
In a single system, the options are:
Option
0 Timed. The keypad sounders and any internal sounders give a low
tone during exit of Level D. Use Command 79 to select the exit time.
1 Instant Set (no exit tone). Use this option to make the system set
without delay or exit tone.
2 Silent Set. Use this option to make the system set without an exit
tone. Use Command 79 to program the exit time.
3 Makes the Level D exit mode the same as Level A.
In a partitioned system, the options are:
Option
0 Timed. Use this option if Partition D sets after an exit time selected
using Command 79. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminate. Use this option if the user completes setting the partition
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option.
2 Final Door Set. Use this option to complete setting the partition by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option.
3 Instant Set (no exit tone). Use this option to make the system set
without delay or exit tone.
4 Silent Set. Use this option to make the system set without an exit
tone. Use Command 79 to program the exit time.
5 Lock Set. See Command 39 on page 20 for an explanation.