Cooper Security Homelink 75 Guide de l'utilisateur Page 76

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 75
Programming Reference - Reporting 7510r
Page 72
telephone number before accepting a request to
process a SMS message.
Line Fail Reporting
This menu lets you program the system to respond with
either audible or silent alarms when the control unit
detects a fault on one of its communication lines. To
program Line Fail Reporting select
Reporting, Line Fail
Reporting.
If you have a GSM or ISDN module you can set up Line
Fail reporting for either the PSTN line attached directly to
the control unit, or for the attached module.
The exact response depends on whether the system is set
or unset, as follows:
Disabled.
The control unit does not monitor the telephone line.
Audible.
If the system is unset then the system logs the
event. The control unit produces a short audible tone
every minute. Entering a valid access code silences
the sounders and the display indicates a telephone
line fault. The system can be set again with the line
fault present.
If the system is set then the control unit logs the
event but does not give any tone or display. The
control unit cancels any programmed siren delay if
the line is out of order when an alarm occurs.
Note: Audible response is the NSI recommendation for
line fault.
Silent.
If the system is unset then the display indicates a
telephone line fault and the control unit logs the
event. The system may be set again with the line
fault present.
If the system is set then the control unit does not
give any indication or tone but does log the event.
The control unit cancels any programmed siren delay
if the line is out of order when an alarm occurs.
Vue de la page 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 82 83 84

Commentaires sur ces manuels

Pas de commentaire