9651 3. Installation
11772232 Page 23
Wiring Keyswitches
To allow a user to set and unset the system using a keyswitch, connect a
fixed position or spring loaded (momentary) key switch to a zone input. When
programming the control unit select zone type (KM) for momentary or (KF) for
fixed position keyswitches. See Command 185 for keyswitch auto-reset.
Figure 18 shows the connections for a keyswitch.
Fixed Keyswitch (KF)
Keyswitch CC FSL System
OFF Closed 2k2 Unset
ON Open 6k9 Set
Momentary Keyswitch (KM)
Keyswitch CC FSL System
Operate Close-Open-
Close
2k2-6k9-2k2 Unset
Operate Close-Open-
Close
2k2-6k9-2k2 Set
Figure 18. Connecting a Keyswitch
Note:
If you connect a keyswitch as a zone, without an interface, it can be used
to set and unset the level to which the zone is assigned.
Wiring a 9928 Keyswitch Interface
The 9928 keyswitch interface is no longer available for purchase, but is
supported in existing installations. Figure 19 shows the connections. You can
fit only one 9928 in a system.
M/C
M/C
M/C
0V
12V
CLK
D
ATA
ET
PA
SET
RDY
9928
COM
KS2
KS1
Full
Off
Part
Full
Part
T
AMP
Momentary
Continuous
T
okeypadbus
on control unit.
Latched
Momentary
Figure 19. Connecting a 9928 Keyswitch Interface
4k7
2k2
CC Wiring CCT(n)
CCT(n)
FSL Wiring