Cooper Security 9751 Guide de l'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
20 496661
3. Press to toggle the display between the time and date of the event and
the log report. Press 1 to see earlier events in the log. Press 3 to see
more recent events.
4. Press to stop using the log.
Table 1. Log Event Codes
Message Meaning
EEProm Fail Internal error, contact Installer.
Codes Defaulted The access codes have been reset to default values.
Clear Log The system programming has been returned to default values.
System Startup System was started (power applied).
System Tamper Bell or bell wiring tamper.
System Tamp Rst System tamper reset.
Lid Tamper Control unit lid opened.
Lid Tamper Rst Lid tamper reset
Sounder Tamper Sounder lid opened.
Sounder Tamp Rst Sounder tamper reset.
Unn On-Site User nn (see next page) put system into programming mode.
Unn Off-Site User nn (see next page) put system out of programming mode.
Unn Change User nn (see next page) changed their user code.
Unn Delete User nn (see next page) deleted their user code.
Unn L# Set User nn (see next page) set Level #.
Unn L# UnSet User nn (see next page) unset Level #.
U12 L# Set Telecommand set Level #.
U12 L# UnSet Telecommand unset Level #.
U13 L# Set Keyswitch set Level #.
U13 L# UnSet Keyswitch unset Level #.
System Rearmed System auto rearmed.
Unn Znn Omit User nn (see next page) omitted zone nn.
Unn Znn Unomit User nn (see next page) re-instated zone nn.
Fire Znn Alarm Fire alarm at zone nn.
Fire Znn Rstr Fire alarm at zone nn restored.
Fire Znn Reset Fire alarm at zone nn reset.
PA Znn Alarm Panic alarm at zone nn.
PA Znn Rstr Panic alarm at zone nn restored.
Unn System Unset User nn (see next page) unset system.
PA Knn Alarm Panic alarm started at keypad nn.
Burg Znn Alarm Intruder alarm at zone nn.
Set Fail Znn Setting failed because of zone nn.
Burg Znn Rstr Intruder alarm at zone nn restored.
Tamper Znn Tamper at zone nn.
Knn Missing Keypad nn missing.
Knn Restore Keypad nn restored.
Knn Tamper Tamper at keypad nn.
Knn Excess Keys Too many keys pressed at keypad nn (someone may be trying to
guess the access code).
Low Bat Znn Radio detector nn has reported a low battery.
Low Bat Znn Rstr Low battery report from zone nn restored.
RF Jamming Radio jamming detected.
RF Jamming Rstr Radio jamming stopped (restored).
RF Sup Fail Znn Radio detector nn is not responding.
RF Sup Rstr Znn Radio detector nn is responding again (restored).
4. Special Functions