4. Programming
34 496791
To change: Key-in: Notes Default
Level A Exit Mode 39 0 Timed Y
1 Terminated
2 Final door
For a single system n is:
3 Lock Set
For a partitioned system n is one of:
3 Instant set
4 Silent (kpd beeps at end of setting period)
5 Lock Set
System Auto Re-Arm 40 0 Rearm Never Y
1 Rearm 1
2 Rearm 2
3 Rearm 3
4 Rearm Always
Bell Delay 41 0 No delay Y
1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes
Bell Duration 42 1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes Y
Level A Entry Time 43 1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level A Exit Time 44 1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Entry/Exit Volume 45 0 No Entry/Exit tones from Loudspeaker
(Single system only.) n EE tone volume from LS (1=low, 9=max) 5