4. Programming
496791 63
Level C Exit Time (Command 75)
This Command sets the exit time for part set C or Partition C. See “Program-
ming Commands” for options.
Level D Exit Mode (Command 76)
Command 76 specifies the exit mode for part set D or Partition D. For a
single system the options are:
Option 0 The keypad sounders and any internal sounders give a low tone
when entering part set Level D. Use Command 79 to select the
exit time.
Option 1 Instant Set (no exit tone)
Option 2 Silent Set. Use Command 79 to program the Exit time. At the end
of the exit time the keypad gives a double beep confirmation tone.
Option 3 Makes the Level D exit mode the same as Level A.
For a partitioned system the options are:
Option 0 The keypad sounders and any internal sounders give a full tone
when setting Partition D. Use Command 79 to select the exit time.
Option 1 Terminate. Use this option if the user completes setting the
Partition by pushing an exit terminate button connected to a
keypad. Note that the exit time is infinite in this option.
Option 2 Final door set. Use this option to complete setting the Partition by
closing a door fitted with a Final Exit zone detector. Note that the
exit time is infinite in this option.
Option 3 Instant Set (no exit tone)
Option 4 Silent Set. Use Command 79 to program the Exit time. At the end
of the exit time the keypad gives a double beep confirmation tone.
Option 5 Lock Set. See “Level A Exit Mode (Command 39) for an explana-
tion of Lock Set.
Note that the keypads give a double beep confirmation tone at the end of all
setting modes.
Level D Alarm Response (Command 77)
Command 77 specifies the alarm response for part set D or Partition D. In a
single system:
Option 0 Keypad sounders only.
Option 1 Internal sounders and keypad sounders.
Option 2 Local alarm (internal and external sounder only).
Option 3 Full alarm (communication and internal/external sounders).