4. Programming
48 496791
setting and unsetting. If the zone is violated the control
unit starts a tamper alarm, shows the message “AM
Tamper” on the keypad display, and logs the event as a
zone number with Anti Mask.
Forbikobler (FB) (Key in 14). This zone type is a Scandinavian entry/exit
zone. Use this type on zones connected to stand alone
external keypads or access controllers. The zone oper-
ates as a normal entry/exit zone but when triggered by
the external keypad during the exit time the control unit
stops the exit time and sets the system. If the zone is
triggered while the system is set then the control unit
starts the entry time.
Zone Attributes
Specific zone types can have one or more attributes programmed by the digit
after the zone Command and type. (To remove an attribute, key in the
attribute digit again.)
Chime (C) (Key in 1) When enabled by the user, the system gives
a non-alarm warning tone when any zones programmed
as ‘Chime’ are opened. This facility operates only while
the system is unset.
Notes:
1. ‘Chime’ is available only for Normal Alarm, Final Exit, Entry Route and Shock
Analyser zone types.
2. To make chime available from the keypad sounders but not the internal
sounder then program Command 22 with option 0.
Soak Test (S) (Key in 2) Use this zone attribute if you want to place
under long term test a detector that you suspect is giving
false alarms. Zones with this attribute are disabled for 14
days after you return the control unit to user mode. If the
zone is opened while the system is set then the Service
LED glows and the control unit logs the event as a “Soak
Test Fail Zn” (n is the zone number) without sounding any
bells or starting signalling. The Service LED stays alight
until the Engineer resets the system. After midnight on the
14th day the control unit returns the zone to normal use.
Note: Soak test is available only for Normal Alarm, Entry Route, Technical and
Shock Analyser zone types.
Double
Knock (2) (Key in 3) Zones with this attribute will cause an alarm
condition only if one or more sensors generate two alarms
events within a five minute time window, or if one zone