4. Programming
496791 43
Leaving Programming Mode
When all programming has been completed:
1. Key-in ‘99 ’ at the keypad
The display shows:
2. Press .
The display shows:
followed by the time and date.
The system is now in user mode.
Note: If there is a fault, for example an open tamper circuit, the display shows this
and will not return to Day mode. Press and rectify the faults.
Engineer Reset
To perform an Engineer Reset:
1. Check that the display is showing the alarm condition.
2. Key in 0 followed by the Engineer’s code (default 7890), followed by 99 .
The display shows the time and date.
Re-entering Programming Mode
You can go back into programming mode whenever the system is unset and
not in alarm:
1. Key in 0 followed by the Engineer’s code (default 7890).
The display shows:
You are now in programming mode.
Restoring the Access Codes (1st stage reset)
If the user and/or engineer codes are lost, then:
1. First remove mains power and then open the case and disconnect the
battery.
2. Identify the NVM Reset pins and Kick Start pins on the main pcb (see
Figure 3).
3. Short the NVM Reset pins together using a small wire link. Short the
Kick Start pins together with another small wire link.
4 Reconnect the battery.
5. Remove the shorts from the NVM Reset pins and Kick Start pins.
The control unit loads the factory default access codes:
User 1: 1234, Engineer: 7890.
6. Close the control unit and apply mains power.
7. Carry out an engineer reset.