i-on16 Installation
Page 13
Note: Do not site two or more keypads closer than one
metre together, otherwise their prox readers will
interfere and be unable to read tags.
Fitting
Use M5 25mm countersunk screws in at least three fixing
holes when mounting the back of the keypad on the wall.
Figure 8. Screw Keypad Back Box to Wall
Connect Keypad to End Station
Cable Type
In general, the control unit requires standard 7/0.2 un-
screened alarm cable for wiring to keypads.
Screened cable may prove necessary if the installation
site has equipment that produces high levels of R.F.
(Radio Frequencies), for example welding equipment. If
screened cable is required, you should keep to the
following guidelines:
1. Avoid earth loops by connecting the screen on the
cable to mains earth at the end station but not at the
keypad.
2. The continuity of the cable screen is most important
and screens MUST be continuous along the full length
of the cable.
3. If the cable enters any metal enclosure, ensure the
screen is isolated from the case.