Programming i-on16
Page 34
Zone Attributes
The attributes available are:
Chime
When enabled by the user, the system gives a non-
alarm warning tone when any zones programmed as
‘Chime’ are opened. This facility operates only while
the system is unset.
Part Set
When a user presses button B (part set), the control
unit sets only those zones where the Part Set
attribute = “Yes”. (See also “Part Set Exit Mode” on
page 40 ).
Force Set Omit
The user can set the system while a zone with this
attribute is open (active). (You must enable this
feature in the System Options – Force Set menu See
page 44.)
Note: Some attributes are not available for certain zone
types. The display shows the available attributes.
External Siren
The external siren is a weather-proof battery powered
siren designed to operate on external walls. In an alarm
the control unit triggers the external siren at the same
time as the internal siren. The 760 external siren runs for
either: five seconds, three minutes, or 15 minutes
depending on the position of a link within the sounder.
To program the external siren select Detectors/Devices –
External Radio Siren .
Adding an External Siren
To make the control unit learn the ID of an external
siren:
1. Select Detectors/Devices – External Siren – Add/Del Ext
Siren.
The display shows two possible “memory slots” for
external sirens. A slot already allocated to a siren
shows a “*” at the beginning of its line.
2. Select an empty memory slot.