i-on16 Installation
Page 17
If you wish run mains cable through the side of the case,
make sure that they are horizontal for the last metre
before entering the case.
Mains Connection
Figure 13 shows the mains connection. Connect to a
suitable supply using a double pole disconnect device in
accordance with EN60950-1.
L
N
T 400mA 250
V
230V ~50Hz 200mA
Figure 13. Mains Connection
Caution: Do not apply power at this point.
4. Connect Wired Peripherals
The end station pcb provides four connectors for wired
outputs. Each of these outputs is driven by a transistor,
and is capable of sinking a maximum 500mA when
active. The outputs are 0V when active, +12V when
inactive.
Figure 14 shows examples of connecting wired
peripherals.