i-on16 Programming
Page 51
Enabled
The system rearms Channel 3 once the siren timer
has expired. Once the Channel is rearmed, the
system is ready to report any new alarm. The system
bypasses any detectors that are still violated.
Notes:
If a Final Exit Zone is triggered, Channel 3 becomes
active at the end of the Programmed Entry time.
Send Tamper as Burg
When using CID reporting this option allows you to
program the control unit to send tampers as alarm.
If you select Disabled, (the default) then the control unit
sends all CID messages as specified in Reporting – Alarms
– CID Events.
If you select Enabled then for full alarm response the
control unit sends tampers as burglary (BA) and sends
Contact ID 130 in place of Contact ID 137.
Dynamic Test Call
In dynamic testing the system makes a test call 24 hours
after the last alarm communication. To enable dynamic
testing select Reporting – Alarms – Dynamic Test Call –
Enabled.
Static Test Call
In static testing the system makes a test call either on:
Every day at one particular time of day or
On the same day of every week, or
On one day every month.
To make test calls at a set time every day select
Reporting – Alarms – Static Test Call – Daily. From the
display select a number between 01 and 24 to choose the
time of day for the call. For example, select 18 to
program the control unit to make a static test call at
6:00pm every day.
To make test calls on the same day every week select
Reporting – Alarms – Static Test Call – Weekly. From the
display select the day of the week on which the call
Commentaires sur ces manuels