Introduction Engineering Manual
2
Table 1: Differences between control panel types
Panel Type
Feature M800 M1000
1
M2000
EN50131-1/PD6662 grade
(max)
3 3 3
Maximum zones
2
40 144 264
Wards 4 8 8
Ward groups (part sets) 4 4 8
User codes (including 1
engineer code)
50 100 251
Network ports 2
3
2
3
2
3
On-board zones 8 8 8
Digital communicator outputs 16 16 16
On-board transistor outputs 2 3 3
On-board relay outputs 1 2 2
On-board modem Yes Yes Yes
CPA6 output module port Yes Yes Yes
No. CPA6 modules supported
4
5 18 31
Serial port
5
No Yes Yes
Event log entries 1000 2000 3000
Shunt groups 5 10 10
The following figures illustrate the network architecture of each type of panel.
)
See "Compatible Devices" on page 6 for details of compatible devices, including keypads,
LECs, MSNodes, MRNodes, and MSPSUs,
1
The M1000 is obsolete.
2
Each panel includes eight on-board zones.
3
On an M2000 networks 1 and 2 can both connect to keypads or Nodes. On a M800/M1000 network 1 can
connect to keypads and LECs only.
4
CPA6OM is now obsolete.
5
All panels include a USB port.