Cooper Security M2000 Guide de l'utilisateur Page 97

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 180
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 96
Engineering Manual Engineer Menu 1-9
89
29 – Radio PA Audible/Silent
Silent – The control unit triggers a silent PA alarm if a telecommand or radio PA starts a
panic alarm. In addition, the keypad does not display any alerts, but triggers the
appropriate outputs.
Audible – The control unit generates PA tones from the sounder and operates the strobe
when a telecommand or radio PA starts a panic alarm, displays alerts on the keypads, and
triggers the appropriate outputs.
30 – Silent Alerts
Use this command to disable the Alert fault tones. When enabled (default) the system
gives an alert tone and displays alerts on the keypad.
Y (Silent). The display shows alert messages for faults, but does not sound alert tones.
N (Audible). The display shows alert messages, and the system gives alert tones.
31 – Bus Cut Confimed/Unconfirmed Alarm
If an intruder cuts one or more of the bus cables then the control unit can report the event
as either a confirmed or an unconfirmed alarm. Use this command to select one of these
two options.
)
To ensure that this feature works correctly program Tampers as Tampers/Alarms to
“Tampers as Alarms”. See page 91.
Confirmed. The control unit reports a cut bus cable as a confirmed alarm.
Unconfirmed. The control unit reports a cut bus cable as an unconfirmed alarm.
Option 1-9-2: Choosing DD243 Configuration Options
(For defaults see page 133.)
1 – Confirmation On / Confirmation Off
Confirmation On – Select this option if you want to use the DD243 rules. Selecting the
option enables the panel to generate "confirmed" alarms.
A confirmed alarm occurs in a ward when at least two separate zones trigger within the
Confirmation time (page 62), providing the ward is set and the Entry Delay timer (page 61)
is not running. A confirmed alarm indicates that the alarm condition has a low probability
of being a false alarm. Generally, police will respond only to confirmed alarms. Note that
the second detector may be in a separate ward from the first detector. The control panel
reports the confirmed alarm for the ward containing the second detector.
If you do not select Confirmation On, all alarms are unconfirmed and require only one
zone to trigger in the alarm state (e.g. a Normal Alm zone while the system is set).
)
Please refer to the descriptions below for further information about the effects of
Confirmation On.
Confirmation Off – Selecting this option prevents confirmed alarms from being generated
and disables any output configured to follow a confirmed alarm.
2 – Sndrs on Unconf / Sndrs on Confirm
These options are relevant only if you have selected Confirmation On.