Engineer Menu 1-5 Engineering Manual
74
Overriding a Time Switch’s Status
At any time you can change the status of a Time Switch: if it is On you can turn it Off, and if it is
Off you can turn it On. To do this:
Select Option 1 - 5 - 5 .
Press | or ¬ to select a Time Switch. If you wish, you can key in the number of the Time Switch
to select it directly (use leading zeroes for timers 1 to 9).
Press [ to start editing the Time Switch.
The bottom line of the display shows “Status:” and the word “On” or “Off”.
Press ] again.
The display shows a “>” cursor just after the work “Status:”.
Press r to change the status. (Press r a second time if you change your mind.) The control
unit changes the status of the output.
Press [ to save your changes.
Example: Auto Setting
Staff work normal office hours from Monday to Friday. The panel needs to be unset at 8am
from Monday to Friday; the panel need to be set at 7pm on those same days. There are bank
holidays at April the 1st and Christmas.
Configuration:
Config Value
Auto-Set Timer 1 Unset Time 08:00 hrs
Unset Days Of Week Mon, Tues, Wed, Thurs, Fri
Set Time 19:00 hrs
Set Days Of Week Mon, Tues, Wed, Thurs, Fri
Ward List 1
Exception periods 01, 02
Exception period 01 Start Date 1
st
Apr
StartTime 00:01
End Date 1
st
Apr
End Time 23:59
Exception period 02 Start Date 25
th
Dec
Start Time 00:01
End Date 2
nd
Jan
End Time 00:01
Actions:
During the normal working week:
Day Time Auto-Set Timer Action
Fri 19:00 hrs Set
Mon 08:00 hrs Unset
Mon 19:00 hrs Set
Tues 08:00 hrs Unset
Tues 19:00 hrs Set
Wed 08:00 hrs Unset
Wed 19:00 hrs Set