Programming Reference - Partitions 7510r
Page 36
Final Door Set.
Use this option to complete setting the partition by
closing a door fitted with a Final Exit zone detector.
Note that the exit time is infinite in this option.
Note: Do not try to make a PIR zone act as a Final Exit
for a partition. Radio PIR detectors have a “lock out”
period after each activation in order to conserve
battery power. When you set (or part set) a partition
a PIR may still be in lockout, during which it cannot
send a signal to complete the setting process.
Instant Set.
The partition sets immediately and without any tones.
Silent Set.
The partition sets after the exit time programmed in
the Entry/Exit Time menu but does not give any exit
tones. When the partition sets the control unit gives a
double beep.
As Partition 1
This option is available for partitions 2, 3 and 4.
When you select this option the system uses the
same setting mode as partition 1.
The control unit gives a double beep confirmation tone at
the end of all setting modes.
If you select Final Door Set exit mode then the system
allows a seven second settling time after closing a final
door.
Exit Time/Entry Time
You can give each partition separate entry and exit times.
The times can each take one of the following values
(seconds):
10, 20, 30, 45, 60, 120.
Alarm Response
You can give each partition an individual alarm response.
The responses available are:
Siren
Local alarm (siren only).