7510r Programming Reference - System Options
Page 45
There are three options available:
Off
The user cannot force set the system, even if you
have applied the force set zone attribute to any
zones.
Confirm
The user can force set the system. Users employing a
telecommand to set the system must operate as
follows: 1) the user presses the appropriate button to
set the system, 2) the control unit starts an error
tone, 3) the user presses the same telecommand
button to confirm that they wish to continue setting
the system.
On
The user can force set the system. Users employing a
telecommand need only press the telecommand
button once to complete setting the system.
RF Siren Options
This menu allows you to select how the radio siren
responds during Fire, Burglar or PA alarms. There are two
options:
Siren + Strobe
The radio siren operates both siren and strobe in an
alarm.
Strobe
The radio siren operates the strobe only in an alarm.
Panel Siren
When installing an alarm system that complies with
PD6662:2004 the control unit cannot use any built in
sounder. To disable the built-in sounder select: System
Options, Panel Siren
. There are two options:
No The siren within the control unit is disabled.
Yes The siren within the control unit is enabled for all
alarms.