4. Programming
496964 Page 109
Note: 1. If the control unit is using Fast Format signalling, and has sent a Burg
to the ARC, the control unit activates the output pin assigned to Comms
Acknowledge when the ARC returns a Comms Acknowledge signal.
2. The control unit delays reporting/logging either mains loss, or exiting
engineering with mains loss, by 15-18 min (chosen at random). If you
select a Scandinavian default in Command 0, the control unit waits at
least 60 minutes before reporting.
159: Invert Plug-by Outputs
By default, plug-by outputs have a positive voltage when inactive and this is
removed when the output is active. This Command inverts that logic so that a
positive voltage is applied when the output is active.
Option
0 +ve removed to trigger: the output is positive when inactive and goes
to zero when active.
1 +ve applied to trigger: the output floats when inactive and goes
positive when active.
160: Confirmed Alarm Timer
Note: Enable Alarm Confirmation (Command 89) to access this Command.
This Command controls a timer. The timer starts when an alarm is triggered
for the first time. If a second alarm is triggered before the timer expires, the
control unit transmits a confirmed alarm to the ARC. You can set the timer to
any value in minutes between 001 and 999. For DD243: 2002 compliance, set
confirmation time to between 30 minutes (default) and 60 minutes.
161: Internal Sounder on Confirmed or Unconfirmed Alarm
Note: Enable Alarm Confirmation (Command 89) to access this Command.
This Command selects whether the control unit will operate the internal
sounder for a confirmed alarm or for an unconfirmed alarm. In a partitioned
system, the internal sounder is available only for Partition A; other partitions
use keypad sounders only.
Option
0 Control unit operates the internal sounder for an unconfirmed alarm.
1 Control unit operates the internal sounder for a confirmed alarm.