2. Technical Description
Page 18 496964
Radio Expander PCB Layouts
The 9955, and its replacement the 9960, are Class VI radio expanders. Class
VI is the grading given by the British standard for Wirefree Alarm Systems and
is required for signalling systems that require a police response. They receive
signals from the radio detectors on a frequency of 868.6625MHz. Both models
are CE tested to EN 50081-1 and EN 50082-2.
9955 Radio Expander
The 9955 radio expander supports eight wirefree zones. Figure 7 shows the
layout of the PCB.
10
8
7
13
9
12
2
3
6
1
15
0V 12V CLK DATA
14
4
5
11
1. 2 x 7-segment display 9. Tamper switch
2. Select button 10. Supervision jumper
3. Delete button 11. Address jumper
4. Green "Pass" LED 12. Learn sensor
5. Red "Fail" LED 13. Jamming response jumper
6. Sounder 14. Radio section
7. Cable entry 15. Aerial
8. Bus connector
Figure 7. 9955 Radio Expander
Refer to the "9955 Installation and Programming Guide" for more details.