4. Programming
Page 62 496964
Enter letters from the keypad one at a time by repeatedly pressing a number
key until the display shows the letter you want. Figure 36 shows which letters
are assigned to each key. If you make a mistake, press C or D to move the
cursor to the letter you want to change and key in the new letter. To delete a
name completely, press D to move the cursor onto the first character of the
name and then press D again to clear the old name.
When you have finished entering the name, press Y.
ABCÆÅÄ DEF
GHI
JKL MNOØÖ
PQRS
TUV WXYZ
Space'():.-!&
Figure 36. Letters Generated by Each Number Key
Zone Types
The following table shows the values available for zone type.
Value Type Description
00 Not Used
(NU)
Identifies zones that are not used. The system ignores
zones of this type. It is not necessary to link the circuit
or anti-tamper connections.
01 Panic Alarm
(PA)
Operating a device programmed as "Panic Alarm" will
start either a silent alarm transmission to the ARC or
an audible alarm, depending on how you have
programmed PA Response (see Command 30). PAs
operate, whether the system is set or unset. PA zones
can be allocated to one or more partitions in a
partitioned system (A–D attributes on page 67) but
these attributes are not available in a single system.