4. Programming
Page 124 496964
Example 2. Double Common Area
You are not limited to having one common area. Figure 40 shows three
partitions sharing two common areas.
Common Area 2
Common Area 1
Partition A
Partition B Partition C
KPD
KPD
KPD
Figure 40. Using two Common Areas
The control unit sets Common Area 1 when users set Partitions A and B. The
control unit sets Common Area 2 when users set Partitions B and C.
Example 3. Allowing Cleaners Access to the Common Area
In this example, three offices share a lobby but the building manager wants to
allow cleaners into the lobby in the evening after all the users have left. To
achieve this, the Installer uses Partition D to protect the lobby (see Figure 41).
Lobby
Common Area
Office A
Partition A
Office B
Partition B
Office B
Partition B
Partition D
KPD KPD KPD
KPD
Z1
Z2
Z3
Figure 41. Allowing Cleaner Access to a Lobby
The Installer places one keypad in each office and one in the lobby. During
programming, the Installer assigns each keypad to one partition, making the
lobby Partition D, and assigns zone 1 to Partitions A, B, C and D, making it
the common area. The Installer then assigns a user code for the cleaners to
Partition D.