496792 21
3. Installation
Zone 1
Zone 2
1
2
2K2 EOL
4K7
Alarm contacts
Tamper contacts
2K2 EOL
4K7
Alarm contacts
Tamper contacts
Yellow
Violet
Red
Gold
4k7
Red
Red
Red
Gol
d
2k2
Figure 12. FSL Connections
Connecting Expanders
Figure 13 shows how to wire 9954 and 9955 Expanders to the control unit.
0V 12V CLK DATA0V 12V CLK DATA
To other keypads
and expanders.
Expander
Control Unit
Figure 13. Connecting 9954 and 9955 Expanders
When fitting a 9954 make sure you place the jumper link on the expander in
the correct position to select either four-wire CC, or two-wire FSL or EOL.
Make sure you use the same wiring type as the control unit. In addition, if you
are connecting more than one expander, you must give each one a unique
address by fitting a jumper to the appropriate addressing pins.
FSL
EOL
Four-wire CC
Two-wire FSL
Two-wire EOL
2
3
4
2
3
4
2
3
4
Zones 9 to 16
Zones 17 to 24
Zones 25 to 32
Do not place jumper
in position 4.
2
3
4
Figure 14. Jumper Positions for Connection Types and Zone Addressing
Note: You can
leave the global
anti tamper
connectors
unlinked if you are
using FSL wiring.