4. Programming
78 496792
Option 2 ensures that if the user unsets the system by means of a proximity
reader or telecommand, they cannot cause a confirmed alarm by wandering
from the entry route. However, if an intruder goes through the front door, they
will eventually cause a confirmed alarm if they are still wondering around the
premises after the entry time has expired.
User Reset After Confirmed Alarm (Command 164)
Note: Enable Alarm Confirmation (Command 89) to access this Command.
If you have enable Alarm Confirmation, and selected Engineer Reset (Com-
mand 33) then you can use Command 164 to select whether the user can
reset the system after a confirmed alarm.
Option 0 Disabled. The user cannot reset the system after a confirmed
alarm.
Option 1 Enabled. The user can reset the system after a confirmed alarm.
Note that DD243:2002 states that the user can reset the system if any of the
unsetting methods mentioned in sections 6.4.2, 6.4.3, or 6.4.6 are used. See
“DD243:2002 ACPO Compliance” at the end of this chapter.