4. Programming
496792 39
To change: Key-in: Notes Default
Level D Exit Time 79 1 10 Seconds
(9752 only) 2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Output 1 Type, one of 81 n
Where n is one of the following:
00 Bell (default) 09 Smoke sensor reset
01 EE follow 10 French Siren Test
02 Armed lamp 11 Strobe Set
03 Set latch 12 Pulse Set
04 Shock sensor reset 13 Pulse Unset
05 Walk test 14 Alarm Confirmation
06 Ready lamp 15 Set Complete
07 24 hour alarm 16 Unset Complete
08 Strobe
Output 2 Type, one of 82 n
See Command 81 for a list of options. Default for Command 82 is 8 Strobe
Output 3 Type, one of 83 n
See Command 81 for a list of options. Default for Command 83 is 3 Set latch
Burg Comms Rearm 85 0 Latch
1 Rearm
Dual Ply Entry 86 0 Off Y
1 On (not recommended in U.K.)
Dual Key Alarm 87 0 Off Y
(Incl. keyswitch PA) 1 On
Alarm Confirmation 89 0 Confirm off (default for rest of World) Y
1 Confirm on (default UK only)
Event Log* 90 1 View earlier events
3 View later events
Cancel viewing
Toggles time/date display
Test Output 1* 91 Output 1 operates, press or to end
test.
Test Output 2* 92 Output 2 operates, press or to end
test.
Test Output 3* 93 Output 3 operates, press or to end
test.
Vue de la page 44