4. Programming
496792 67
Line Fail Response (Command 106)
This Command lets you program the system to respond with either audible or
silent alarms when the system detects a fault on an attached telephone line.
The exact response depends on whether the system is set or unset, as
follows:
Disabled (0) The control unit does not monitor the telephone line.
Audible (1) If the system is unset then the system logs the event. The
keypad produces a short audible tone every minute.
Entering a valid access code silences the sounders and
the keypads indicate a telephone line fault. The system
can be set again with the line fault present.
Note: Audible response is the NACOSS recommendation for line fault.
If the system is set then the control unit logs the event but
the keypads do not give any tone or display. The control
unit cancels any programmed bell delay if the line is out of
order when an alarm occurs.
Silent (2) If the system is unset then the keypads indicate a tel-
ephone line fault and the control unit logs the event. The
system may be set again with the line fault present.
If the system is set then the keypad does not give any
indication or tone but the control unit does log the event.
The system cancels any programmed bell delay if the line
is out of order when an alarm occurs.
Dynamic Test (Command 108)
In dynamic testing the system makes a test call 24 hours after the last
communication. Select option 0 to disable dynamic test calls. Select option 1
to enable dynamic test calls.
Note: Cooper Security Ltd recommend that you chose either Static Test Call (105) or
Dynamic Test Call, but not both at the same time.
Three Way Call - UK only (Command 109)
To use Three Way Call you must make sure that the BT Network Services
Option of ‘Three Way Calling’ is available on the telephone line to which the
communicator is connected.
Three way off (0) Disabled
Three way on (1) Three Way Call.
Operation: If the control unit triggers the communicator
and the communicator detects Off Hook or Incoming
Ringing, the communicator then sends a 80 ms trigger