1. Introduction
Operator Controls and Displays - 9930
Figure 2. 9930 Remote Keypad.
The 9930 keypad has a single line 16 character LCD display that shows first
to alarm information, level status, and programming commands. In addition
there are three LEDs with the following functions:
Glows steadily when mains power is present. Flashes when the
system is working from battery backup.
Glows steadily if a telephone line fault is present.
Glows steadily if:
a) A fault or tamper circuit is active while the system is unset.
b) The system needs an engineer or remote reset.
c) A telephone line fault is present.
In user mode, the keys provide the following functions:
9 Used to start a test of the detectors.
8 Used to start a test of the sounders and strobe.
7 Used to enable or disable the Chime facility.
6 Used to set the internal clock calendar, which provides a time
stamp on log entries.
5 Used to display the log (250 events).
4 Used to change the user access codes.
0 Used to call an ARC to request a download.
Used to enter programming and setting/unsetting commands.
Used to set the system with individual zones (including 24 hour
zones) temporarily omitted.
A,B,C,D Level setting keys. Level A sets the whole system.