4. Programming
496792 59
Level B Final Exit Operation (Command 60)
Command 60 controls how the system will treat Final Exit zones in Part Set
Level B. When the Command option is set to 0 any Final Exit zones included
in Part Set B will continue to act as Final Exit zones during Part Set B. When
the option is set to 1 any Final Exit zones included in Part Set B will act as
Normal Alarm zones during Part Set B.
Level B Entry Route Operation (Command 61)
Command 61 controls how the system treats Entry Route zones during Part
Set B. When the option is set to 0 all Entry Route zones included in Part Set
B will continue to act as Entry Routes during Part Set B. When the option is
set to 1 any Entry Route zones included in Part Set B will act as Final Exit
zones during Part Set B.
Level B Exit Mode (Command 62)
Command 62 specifies the exit mode for Level B.
Option 0 The keypad sounders and any internal sounders give a low tone
when entering Part Set Level B. Use Command 65 to select the
exit time.
Option 1 Instant Set (no exit tone)
Option 2 Silent Set. Use Command 65 to program the Exit time. At the end
of the exit time the keypad gives a double beep confirmation tone.
Option 3 Lock Set. See “Level A Exit Mode (Command 39) for an explana-
tion of Lock Set.
Option 4 Level B exit mode is the same as Level A. The system gives full
volume setting tones.
Note that the keypads give a double beep confirmation tone at the end of all
setting modes.
Level B Alarm Response (Command 63)
Command 63 specifies the alarm response for Part Set B.
Option 0 Keypad sounders only
Option 1 Internal sounders and keypad sounders
Option 2 Local alarm (internal and external sounder only)
Option 3 Full alarm (communication and internal/external sounders).
Level B Entry Time (Command 64)
This Command sets the entry time for Level B. See “Programming Com-
mands” for options.