4. Programming
496792 57
displays it on the keypad. The user calls the ARC and tells them the number
shown on the keypad display. The ARC verifies the user's identity, then
enters the code number into a special programmer. The programmer gener-
ates an ‘Anti Code’, which the ARC gives back to the user. The user then
enters the ‘Anti Code’ at the keypad to reset the system.
Note: To delete a CSID code key in “0000” over the existing code.
Setting Time and Date (Command 51)
The system has an internal clock/calendar which it uses to date stamp the
log. To set the system’s clock/calendar to the correct time and date:
1. Enter programming mode (if you are not already there).
2. Key in 51 at the keypad.
The display shows the current date, for example:
3. Key in two digits for the day number and press . Use leading zeros for
the first nine days of the month.
4. Key in the two digits for the month number and press . Use a leading
zero for January to September.
5. Key in the two digits of the year and press .
The display shows the current time, for example:
6. Key in two digits for the hours of the day and press . Use the 24-hour
clock.
7. Key in two digits for the minutes and press .
The keypad sounder gives a double “bleep” and the display shows
“Installer Mode”. The system sets its internal clock/calendar to the time
you have given it.
Omit Tamper Allowed (Command 52)
This Command ensures that the control unit omits the tamper contacts as
well as the alarm contacts when a user omits a zone. Note that you must give
the zone the omit attribute to allow the user to omit a zone.
Option 0 The control unit omits alarm contacts only
Option 1 The control unit omits both alarm and tamper contacts when the
user omits a zone.
Abort Reset (Command 53)
Option 0 Reset after abort is the same as system reset (see Command 33).
Option 1 Enables customer reset after an abort.
BVVO Supervision (Command 54 (9752 only))
If the alarm system must meet BVVO radio supervision requirements then
select option 1. Once selected, the control unit will give a warning on the
keypad display when a user tries to set the system if a detector has lost