2. Programming Commands
497096, issue 3 Page 11
Value Type Description
17 Battery Fault
(BF)
This zone type is triggered by a fault in the battery in the
external power supply. In a partitioned system, BF zones are
always allocated to Partition A.
18 Power Output
Failure (PF)
This zone type is triggered by a failure in the DC output to the
external power supply. In a partitioned system, PF zones are
always allocated to Partition A.
19 Fault (FL) This zone type triggers a fault condition, causing an alert and
preventing the system from being set. The tamper connection
operates in the same way as a normal alarm zone (type "NA").
Command 139 defines whether a zone of this type can be reset
by a user or only by the installer. Command 140 defines whether
the user can override the fault to set the system. In a partitioned
system, FL zones are always allocated to Partition A.
Zone Attributes
The following table shows the values available for zone attribute, depending
on the zone type. To set an attribute, key in the appropriate value. To unset
the attribute, key in the value again.
Value Attribute Valid for Description
X1
Chime (C) Normal Alarm
(NA)
Final Exit (FE)
Entry Route
(ER)
Shock Analyser
(SA)
When enabled by the user, the system makes
a doorbell-like sound when any zones
programmed as "Chime" are opened. This
facility operates only while the system is
unset.
To make the Chime available from keypad
sounders but not internal sounders, use
Command 22 with option 0.
X2
Soak Test (S) Normal Alarm
(NA)
Entry Route
(ER)
24-hour (24)
Shock Analyser
(SA)
Use this zone attribute if you want to place on
long-term test a detector that you suspect is
giving false alarms. Zones with this attribute
are disabled for 14 days after you return the
control unit to user mode. If the zone is
opened while the system is set (or at any time
for a 24-hour zone), the control unit logs the
event as a "Soak Fail Znn" (nn = zone
number) without sounding any bells or starting
signalling. The control unit returns the zone to
normal use after 14 days, even if the system
is set at the time.