2. Programming Commands
Page 18 497096, issue 3
33: System User/Engineer Reset
To require an engineer reset, select option 1. To permit a user reset, select
option 0 (the default). Certain types of events always need an engineer reset,
irrespective of the option that you choose here:
° Auxiliary 12V supply fuse blown
° Keypad missing or failed
° Remote expander missing or failed
° A low battery at the control unit.
Note: Compliance with DD 243: 2004 (see page 83) requires that Command 33 is set to
option 1. You can use various other forms of reset, such as remote (see Command
23) or anti-code (see Command 50).
34: PA User/Engineer Reset
To require an engineer to reset the system after a PA, select option 1. To
permit a user to reset the system after a PA, select option 0 (the default).
35: First Circuit Lockout
If you select option 0 (Lockout), the first zone to activate during the set cycle
is ignored until the system is unset. This is the default.
If you select option 1 (Rearm), all zones are included at the end of the
programmed bell run time, provided that the first-to-alarm zone is closed and
the number of rearms is not exceeded. While the zone is open, the system
excludes it. If the zone closes after the system rearms, the system includes it
again.
36: Alarm Abort
Users occasionally trigger false alarms by accident. Select option 1 to permit
them to abort under these circumstances.
If a user accidentally triggers an alarm while the system is set, the control unit
transmits an intruder alarm and starts the Bell Delay and Alarm Abort timers.
To abort the alarm, the user must enter a valid access code during the abort
period. If the user enters a valid code within this time, the system transmits a
restore of the intruder alarm and simultaneously transmits an abort.
Select option 0 (the default) to prevent users from aborting alarms in this way.
Note: The Alarm Abort period is controlled by the Alarm Receiving Centre (ARC).