2. Programming Commands
Page 66 497096, issue 3
200: Forbikobler Entry Timer
This command sets the interval between a user entering the premises through
a Forbikobler entrance and an alarm going off, using one of the independent
entry timers configured with Commands 201 to 204. Any of the entry timers
can be assigned to any Forbikobler entrance. Entering the entry code into the
Forbikobler unit starts the selected entry timer.
Option
1 Entry Timer 1 (default)
2 Entry Timer 2
3 Entry Timer 3
4 Entry Timer 4
201 to 204: Entry Timers 1 to 4
Entry timers set the interval between a user entering the premises and an
alarm going off. There are four independent entry timers so that you can set
different intervals for different entrances, reflecting the time required to
complete each entry route.
Note: These replace the level-specific timers available on earlier control units (formerly
set with Commands 43, 64, 74 and 78). They provide a more flexible approach to
timed entry routes, enabling any timer to be selected for any entrance.
Each entry timer can be assigned to any zone of types FE (Final Exit), ER
(Entry Route) and FB (Forbikobler), using the zone programming commands
01 to X40 (see page 7). Set zone attribute X7 to a value between one and
four to select the required entry timer. Opening the zone starts the selected
entry timer.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) requires that the
Entry Timer does not exceed 45 seconds.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Note: By default, Entry Timer 1 is assigned to all relevant zones.