3. TESTING COMMANDS
90: Reading the Event Log
The control unit keeps a log of recent events. The log can contain up to 700
events. Each event is described by a short text message. To review the event
log, make sure the system is in installer mode and then:
1. Key in 90y.
The display shows the most recent event in the log.
2. Key in 1 to show earlier events or 3 to show later events.
3. Key in 4 to show the first event or 6 to show the last event.
4. Press X to leave the log.
The table on the following pages shows the messages that can be recorded in
the event log. Column 1 lists messages shown on the keypad displays and
column 2 lists corresponding messages in the printed log (9853 only). Each
event in the printed log is preceded by the date and time in numerical format.
To avoid multiple entries being made for the same fault condition, no more
than three events of the same type will be recorded for the same zone in the
same set period.
Note: The log is protected and cannot be erased by the Installer or a user.
In the log, users and devices are represented by numbers:
U00 Installer U54 Telecommand
U01 User 01 U55 Keyswitch
U02 to U49/50 Users 02 to 49/50 U56 Remote reset
U50 Guard code (if set up) U57 Download
U51 Duress code
U52 Control unit
U58 Virtual keypad
(Downloader)
U53 Idle U59 Forbikobler