2. Programming Commands
497096, issue 3 Page 35
77: Level/Partition D Alarm Response
This command sets the Alarm Response for Level or Partition D.
In a single system, the options are:
Option
0 Keypad sounders only.
1 Internal sounders and keypad sounders (default).
2 Local alarm (internal and external sounder only).
3 Full alarm (communication and internal/external sounders).
In a partitioned system, the options are:
Option
0 Keypad sounders only.
1 Local alarm (internal and external sounder only).
2 Full alarm (communication and internal/external sounders) (default).
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) requires that
Command 77 is set to option 2 in a partitioned system.
78: Not used
Level D Entry Time has been replaced by Command 201–204.
79: Level/Partition D Exit Time
This command sets the Exit Time for Level or Partition D.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Note: In a single system, you cannot change the operation of Final Exit and Entry Route
zones assigned to Level D as you can with Levels B and C (see Commands 60, 61,
70 and 71). For this reason, Cooper Security recommends that you use Level D for
simple applications only.
80: Forbikobler Chime
This command links the bell push on the Forbikobler keypad to the Chime on
the system, so that pressing the bell operates the sounders.
Option
0 Off. Pressing the bell push does not operate the sounders (default).
1 On. Pressing the bell push operates the sounders.