2. Programming Commands
497096, issue 3 Page 13
For information on how zones behave in linked partitions, refer to "Common
Areas" on page 78.
Zones and Partitions
In a partitioned system, you can assign some zone types to two or more
partitions, and some zone types to one partition only.
One partition only More than one partition
Panic Alarm (PA)
Fire (FR)
24-hour (24)
Technical (TC)
Smoke Detector (SD)
Keyswitch – Momentary (KM)
Keyswitch – Fixed (KF)
Normal Alarm (NA)
Final Exit (FE)
Entry Route (ER)
Shock Analyser (SA)
Keybox (KB)
Anti-Mask (AM)
Forbikobler (FB)
Use those zone types that can be assigned to more than one partition to
create a common area (see page 78).
Some zone types are not assigned to a partition: AC Fail (AC), Low Battery
(LB), Battery Fault (BF) and Power Output Fault (PF). The Fault zone type
(FL) is always assigned to Partition A.
20: Change Engineer Code
Note: 9x5x control units support six-digit access codes as well as the standard four-digit
codes. Command 56 sets the code length.
To change the Engineer Code:
1. Make sure you are in installer mode.
2. Press 20y
The display shows:
20:Code
3. Key in a new Engineer Code.
The display shows:
20:Code xxxx
4. Press y
If Guard Code is enabled (Command 181), the display shows:
20:Guard
3. Key in a new Guard Code.
The display shows:
20:Guard xxxx
4. Press y