i-on40 Installer Mode Programming
Page 13
full alarm. If a technical alarm zone is activated (and
the control unit correctly programmed, see page 60 )
then the control unit starts communication and logs
the event.
If the technical alarm occurs while the system is set,
then system makes no audible alarm. When a user
unsets the system the keypad shows an alert.
If a technical alarm zone is activated while the
system is unset then the system starts an alert
immediately and gives a brief tone from the keypad
every few seconds. When a user enters a valid access
code the keypad stops the tone and displays the zone
causing the alarm.
When the user acknowledges the alert by pressing Y
the control unit resets the technical alarm ready for
the next event.
Key Switch Momentary (08).
Use this zone type to connect a momentary keyswitch
to a single zone.
In a Part Setting system the keyswitch can Full Set or
unset.
In a Partitioned system you can allocate the
keyswitch to one or more partitions.
Each time a user operates the keyswitch the control
unit changes the current set state.
Key Switch Latched (09).
Use this zone type to connect a fixed position
keyswitch to a single zone.
In a Part Setting system the keyswitch can Full Set or
unset. As with Momentary keyswitches, you can
allocate the zone to one or more Partitions (see
above).
When the user closes the keyswitch contacts the
control unit sets the allocated Partition. When the
user opens the contacts the control unit unsets the
allocated Partition.
Notes:
1. The keyswitch zone types are intended for use on
zones that connect to an access control keypad,
electronic key or other type of hardwired device used