i-on40 Installer Mode Programming
Page 25
1. Select Detectors/Devices – External Siren – Add/Del Ext
Siren.
The display shows four possible “memory slots” for
external sirens. A slot already allocated to a siren
shows a “*” at the beginning of its line.
2. Select the siren you want to delete.
The display shows the message “Delete Ext Siren”.
3. Press Y to make the control unit “forget” the siren ID
learned into that memory slot.
The control unit deletes the siren’s identity, removes
the “*” from the beginning of the line, and gives a
double beep.
Info Modules
The 771r Info Module is an external display module that
can show the setting state of the system or one or more
partitions. You must teach the identity of the i-on40
control unit to each Info Module that you wish to use.
If you wish to allocate an Info Module to individual
partitions then you must fit the appropriate jumpers
within the Info Module (see the 771r Installation Guide
supplied with the Info Module).
Adding an Info Module
To add an Info Module:
1. Select Detectors/Devices – Info Module .
2. Make sure the Info Module is in Learn Mode (consult
the 771r Installation Guide).
3. Select Teach Info Module.
The display shows the message “Is the receiver is in
learn mode?”.
4. Press Y on the i-on40 keypad.
The Info Module should beep twice to confirm that it
has learned the identity of the control unit.
The keypad display shows “Did the receiver beep
twice?”.