i-on40 Installer Mode Programming
Page 49
This option lets you change the zone wiring type. Note
that there are several options of resistor values for FSL:
the keypad display shows the alarm contact resistor/end
of line resistor values for each option.
If you select “4 Wire CC” then the control panel provides
eight wired zones, numbered zone 01 to zone 08.
If you select any of the FSL options then the control unit
provides 16 wired zones, numbered zone 01 to zone 16.
See i-on40 Installation Guide for wiring details.
User Access
To give users access to various system facilities select
System Options – User Access. Press the u or n keys to
scroll up or down the list on the display. To allow access
press > repeatedly until “Yes” appears next to the
selected option. To deny access press > until “No”
appears next to the selected option. Press Y when you
have finished.
PA Keys Active
This option allows users to start an alarm from the
keypads by pressing both the Panic Alarm keys at the
same time. This option applies to all keypads, both radio
and wired, and is not affected by allocating keypads to
specific partitions.
Yes The PA keys on all keypads are functional.
No The PA keys are disabled.
Quick Set
Note: If you enable the quick set keys the control unit no
longer complies with EN50131.
This option controls the operation of the A, B, C or D
keys.
Yes It is possible to set the alarm system by pressing
A, B, C or D without entering an access code.
No The user must enter an access code (or present a
tag) before pressing the A, B, C or D keys.