Installer Mode Programming i-on40
Page 50
Quick Omit
This option allows users to omit a zone that is active (has
it’s alarm contacts open) while they are setting the
system. The zone must have the Omittable attribute (see
page 16).
Yes By pressing Y the user can set the system if there
are zones with the Omit Allowed attribute active.
No The user must go to the Omit Menu to set the
system if a zone is active.
User Code Required
Use this option to ensure that an installer or maintainer
cannot gain access to program the system unless a user
is present:
Yes After the installer/maintainer enters their access
code, the system asks for a user access code
before allowing access to the Installer Menu.
No The installer/maintainer can enter the Installer
Menu by simply keying in their own code.
User Reset
This menu option determines under what circumstances a
user or the installer can reset the system after an alarm.
Zone alarms
(Appears when if System Options – DD243 – Confirmation is
set to “Off”, see page 51.)
Yes The user can reset the system after an alarm
triggered by a zone’s alarm circuit.
No The installer must reset the system after an alarm
triggered by a zone’s alarm circuit.
Zone Tampers
Yes The user can reset the system after an alarm
caused by a zone’s tamper circuits being
triggered.
No The installer must reset the system after an alarm
caused by a zone’s tamper circuits being triggered.
Note: This setting is required for INCERT approval.