Installer Mode Programming i-on40
Page 62
control unit ends the call and then re-attempts to
connect up to a maximum of 15 times.
Alternate.
The control unit reports to one of the two telephone
numbers in the Phone Book.
Operation: The control unit dials the first telephone
number and attempts to connect to the ARC. If it
fails, it will then close down and dial the second
telephone number and attempt to connect to the
ARC. If received and acknowledged on this attempt,
the alarm transmission is complete. If the control unit
fails to connect to the second telephone number, it
will close down again and re-attempt to connect to
the first telephone number. The control unit will
continue to shuttle between the two numbers up to
15 times.
Phone Book
This option appears only when there is an i-sd02 or i-
gsm02 module fitted. Use this menu to store two
telephone numbers that the control unit uses to report
alarms to the ARC. The control unit accepts one
telephone number if you choose Single in the Call Mode
menu, or two telephone numbers if you select Alternate
in the Call Mode menu.
The control unit can store telephone numbers up to 31
digits long.
Use the u and n keys to move the cursor backwards and
forwards through the number if you wish to edit it.
Press
< to delete the digit to left of the cursor.
Press * to add a 2 second pause, if required. The display
shows this as a comma.
IP Network
This option appears if a GPRS or Ethernet module is
fitted. Use it to program alarm receiving company
destinations that the control unit must report to over the
internet.
Note: Before programming the control unit to use the IP
Network please make sure that: