Installer Mode Programming i-on40
Page 16
2. Scroll through the list of partitions for that zone.
Press the > or < keys to change the status of the
zone. “Yes” means the zone is allocated to that
partition.
3. Press Y to save your changes and return to the list of
zones.
When delivered from the factory, or if you restore the
control unit to factory settings, then all zones belong to
partition 1.
Zone Attributes
Note: This menu does not appear if a zone has the type
“Not Used”.
You can assign more than one attribute to a zone. Some
attributes are not available for certain zone types. The
display shows the only available attributes for the zone
type you select.
To enable an attribute for a zone press > or < until the
bottom line of the display shows a “Yes”.
Chime
When enabled by the user, the system gives a non-
alarm warning tone when any zones programmed as
‘Chime’ are opened. This facility operates only while
the system is unset.
Soak Test
Use this zone attribute if you want to place under
long term test a detector that you suspect is giving
false alarms. Zones with this attribute are disabled
for 14 days after you return the control unit to
user/unset mode. If the zone remains inactive for the
whole fourteen days then after midnight on the 14th
day the control unit returns the zone to normal use.
If the zone is activated during those 14 days while
the system is set then the control unit logs the event
as a “Soak Test Fail Zn” (n is the zone number)
without sounding any sirens or starting
communications. The control unit also lights the red
LEDs around the navigation key on the keypad to
alert the user.
You can apply the soak test attribute to Normal