Installer Menu Options i-on160
Page 94
Remotes
The Test menu allows you to test user’s remote control (you must have the
remote control to carry out the test). From the Installer Menu select Test-
Remotes.
The keypad display shows a message asking you to press any button on the
remote you wish to test.
Press one of the remote’s buttons.
The top line of the keypad display shows the remote’s identity, the button you
pressed and the remote’s owner. The bottom line of the display shows the
action assigned to that button and the signal strength.
Press all the other buttons on the remote to test them in the same way.
Note: To test the PA function on a remote use the Test – User Panic Alarms
option in the Installer Menu. A remote’s PA keys are not active in Test –
Remotes option.
User Panic Alarms
The Test menu allows you to test user’s PA transmitters. You must have the PA
transmitter to carry out the test. From the Installer Menu select Test – User
Panic Alarms.
The keypad display shows a message asking you to press the PA buttons.
Press the PA buttons, both at the same time. (The alarm system will not start
a PA alarm as a result.)
The keypad display shows the PA’s owner. The bottom line of the display
shows the signal strength.
Note: To test wired PA buttons use the Test – Walk Test option. To test PA
buttons on a keypad, use the Test – Wired Keypad option. If you attempt to
test either of these functions while in User Panic Alarms you will start a
genuine PA.)
Prox Tags
The Test menu allows you to test a user’s proximity tag. (You must have the
proximity tag in order to test it.) From the Installer Menu select Test – Prox Tag.
The keypad display shows a message asking you to present the tag to the
keypad.
Hold the prox tag up to the keypad.
The keypad display shows the owner of the prox tag.
ARC Reporting
The Test menu allows you to send a test call to either of the two telephone
numbers you have programmed to receive alarm information. The control unit
must have a suitable communications module fitted. ARC reporting must be
enabled (see page 73 ).
From the Installer Menu select Test – ARC Reporting – Tel No 01 (or Tel No 02).
The control unit starts the test call as soon as you press Y. Press X to abandon
the test call.