Installer Menu Options i-on160
Page 62
Note: If a user unsets the system during an alarm, but before the
Alarm Abort period has expired, then they can reset the
system (see page 97).
Zone Tampers
Yes The user can reset the system after an alarm caused by a
zone’s tamper circuits being triggered.
No The installer must reset the system after an alarm caused by
a zone’s tamper circuits being triggered. The alarm abort
period does not apply.
Note: This setting is required for INCERT approval.
System Tampers
Yes The user can reset the system after an alarm caused by a
system tamper, for example the control unit lid or a
keypad being opened.
No The installer must reset the system after a system tamper
alarm. The alarm abort period does not apply.
Note: This setting is required for INCERT approval.
If something activates a tamper, either system or zone, when the system is set
then the control unit classifies this as an unconfirmed or confirmed alarm. The
reset follows the alarm reset option NOT the tamper.
DD243 (UK Only)
Note: This menu is visible only when System Options – Restore Defaults – Country
defaults is set to “UK”.
In order to program your requirements for DD243 select System Options -
DD243. The options available are:
Confirmation
When set to ‘On’ this option enables the features designed to ensure the
system complies with DD243:2004.
Note: When using Confirmation, and the system is programmed for Installer
Reset after an alarm, the user cannot set the system after an alarm until
the installer has carried out a reset.
Confirmation Time
This option determines the length of the confirmation time.
After Entry
Never The control unit turns alarm confirmation off if the user enters by
the entry door (used for DD243:2004 clauses 6.4.2 and 6.4.4).
1 zone The control unit starts a confirmed alarm if the intruder activates
one or more zones, not on the entry route, after entering the
premises through the final exit zone.
2 zones The control unit starts a confirmed alarm if an intruder activates
two (or more) zones, not on the entry route, after entering the
premises through the final exit zone (used for DD243:2004 clauses
Vue de la page 67