Basic Programming Procedures
Programming Before Installation
If you prefer, you can program the control unit before installing the system in
its final location. You will need to temporarily connect a keypad to the control
unit.
It is possible to operate the control unit from battery power (or a 12Vdc
supply) without connecting the unit to a mains supply. However, in order to
start the control unit processor running you must briefly short the Kick Start
pins together after connecting the battery.
When programming the system while it is running on battery only, remember
to leave the Installer Menu before removing power. If you do not do so all your
changes will be lost, see Important! Saving Changes on page 8.
If you wish to program the control unit from a laptop or PC you can do this by
connecting the control unit to your PC via Ethernet. You will need a CAT 5
patch cable and a laptop or PC with a standard web browser. See the separate
publication i-on160EX Web Server Set Up Guide for instructions on how to set
up your PC/laptop and the control unit.
Entering and Leaving the Installer Menu
When you enter the Installer Menu from a keypad, the alarm system is
effectively disabled. While the system is in Installer Menu:
Any other user trying to set the system from a keypad will see the message
“Installer on Site”.
All PAs (including radio PAs), fire alarm zones, 24 hour zones and tampers
are disabled.
Note that this does not apply if you are using the web browser interface from a
PC. If you have logged into the system from a PC then the alarm system is
active.
To Enter the Installer Menu:
1. Make sure the system is unset and showing the
standby screen (time and date).
i-on160EX
12:00 23/07/2010
2. Key in the Installer access code. When delivered
from the factory, at Security Grade 2 the
default Installer access code is “7890”. The
default user code is “1234”. At Security Grade 3
the codes are “567890” and “123456”
respectively.
As you start to key in the code the display
shows:
Enter Access Code:
(* )
When you key in the last digit of the access
code the display MAY show:
User Code Required
( )